{"product_id":"brusa-hypower-obc7-obc768-3p","title":"BRUSA HyPower OBC768-3p OBC7 On-Board Charger","description":"\u003cp\u003eThe BRUSA HyPower OBC768-3p OBC7 is a high-power on-board charger designed for heavy-duty and commercial electric vehicles — from trucks and buses to off-highway and construction machinery. The OBC768-3p supports three-phase AC charging up to 22 kW and manages DC fast charging, including DC contactor driving, across a 400–860 V DC battery range. Its AEC-Q automotive-grade component design, galvanic isolation with reinforced insulation and IP6K9K\/IP6K7D protection make it a robust choice for demanding vehicle platforms.\u003c\/p\u003e\n\u003cp\u003eThe OBC768-3p combines an integrated active power-factor-correction stage with an AUTOSAR-compliant architecture and flash-bootloader software updates, delivering 22.08 kW nominal three-phase output at 95 \/ 96 % nominal\/peak efficiency with a power factor of 0.98 and THDi below 4 %. Charging communication supports CCS1, CCS2, ISO 15118-2, IEC 61851 and DIN Spec 70121, and the vehicle interface runs CAN 2.0a or J1939 at 250 \/ 500 \/ 1000 kbps with CAN-FD hardware readiness. The charger is designed to ISO 26262 with functional-safety goals rated up to ASIL B, an advanced cybersecurity concept with a hardware security module to ISO 21434, UNECE R155 and R156, a passive HV interlock and active\/passive discharge.\u003c\/p\u003e\n\u003cp\u003eThe OBC768-3p integrates into the vehicle through configurable CAN IDs, plug-lock and LED control, inlet management and DC charge-contactor control, and supports scalable power through parallel operation of multiple units. It interfaces with standard charging infrastructure via SAE J1772, IEC 61851 or GB\/T 18487.1, wakes the vehicle over CAN with a Type 2 inlet, and runs from a 9–32 V low-voltage supply with reverse-polarity protection. Shown specifications are valid for the series product and subject to change; some cybersecurity functions remain under ongoing assessment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e OBC768-3p (BRUSA HyPower OBC7)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Three-phase on-board charger (OBC) with DC fast-charge management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input (nominal):\u003c\/strong\u003e 230 \/ 400 V\u003csub\u003eRMS\u003c\/sub\u003e (L–N \/ L–L), 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input Range:\u003c\/strong\u003e 175–288 V (L–N) \/ 300–500 V (L–L)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Current (nominal\/max):\u003c\/strong\u003e 32 \/ 32 A\u003csub\u003eRMS\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e 45–65 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Output Voltage Range:\u003c\/strong\u003e 400–860 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Current (nominal\/max):\u003c\/strong\u003e 36 \/ 36 A\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Power (3-phase):\u003c\/strong\u003e 22.08 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency (nominal\/peak):\u003c\/strong\u003e 95 \/ 96%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Factor (min, load ≥50%):\u003c\/strong\u003e 0.98\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTHDi at full power:\u003c\/strong\u003e \u0026lt; 4%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Modes:\u003c\/strong\u003e HV DC current control; HV DC voltage control incl. HV DC pre-charge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEVSE Interface (AC):\u003c\/strong\u003e SAE J1772, IEC 61851 or GB\/T 18487.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Charging Communication:\u003c\/strong\u003e CCS1, CCS2, ISO 15118-2, IEC 61851, DIN Spec 70121\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVehicle Communication:\u003c\/strong\u003e CAN 2.0a or J1939 @ 250 \/ 500 \/ 1000 kbps; CAN-FD ready (SW upgrade, up to 2\/5 Mbps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVehicle Wake-up:\u003c\/strong\u003e by OBC via CAN (Type 2 inlet); wake-up inputs discrete, CAN, charging plug (PP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLV Supply:\u003c\/strong\u003e 9–32 V\u003csub\u003eDC\u003c\/sub\u003e; reverse-polarity protected (KL15, KL30, KL31, KL30C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiescent \/ Sleep Current:\u003c\/strong\u003e 0.2 \/ 200 mA (max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeatures:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated active power-factor correction\u003c\/li\u003e\n\u003cli\u003eDC fast-charge management incl. DC contactor driving\u003c\/li\u003e\n\u003cli\u003eConfigurable CAN ID\u003c\/li\u003e\n\u003cli\u003ePlug-lock control (up to 2), LED control (up to 4)\u003c\/li\u003e\n\u003cli\u003eInlet management; DC charge-contactor control\u003c\/li\u003e\n\u003cli\u003eParallel operation for scalable power\u003c\/li\u003e\n\u003cli\u003eAUTOSAR-compliant architecture; flash-bootloader SW updates\u003c\/li\u003e\n\u003cli\u003eDigital input × 1 (status via CAN)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e designed to ISO 26262; safety goals rated QM to ASIL B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCybersecurity:\u003c\/strong\u003e to ISO 21434; UNECE R155 and R156 (some functions under ongoing assessment)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHV Safety:\u003c\/strong\u003e galvanic isolation, reinforced insulation, passive HV interlock; passive discharge AC\/DC 5 \/ 120 s; HIPOT 2.4 \/ 2.9 kV\u003csub\u003eDC\u003c\/sub\u003e; insulation resistance 30 \/ 5 MΩ (start\/end of life)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e IP6K9KD and IP6K7D (mated) \/ IPxxB (unmated); ISO 20653\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e 50\/50 water\/glycol; flow 10 \/ 20 l\/min (nom\/max); pressure drop ≤ 100 mbar @ 10 l\/min, 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoolant Temperature:\u003c\/strong\u003e −30°C to +65°C (full power); −40°C to +85°C (reduced power)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e −40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Altitude:\u003c\/strong\u003e 4000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards \/ EMC:\u003c\/strong\u003e UNECE R10, RoHS; CISPR25\/32, ISO 7637\/10605\/11452, IEC 61000-6; electrical safety ISO 17409, ISO 6469, LV123, IEC 60664\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService Life:\u003c\/strong\u003e 40,000 charging hours \/ 15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (without connectors):\u003c\/strong\u003e 97 × 355 × 481 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (dry, max):\u003c\/strong\u003e 16.8 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Specifications valid for the series product; subject to change.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/6863\/2659\/files\/Brusa_Hypower_OBC768-3p_Datasheet.pdf?v=1781834894\" style=\"display: inline-block; padding: 10px 16px; border: 1px solid #d9d9d9; border-radius: 6px; text-decoration: none; font-weight: 600; color: inherit; min-width: 260px; text-align: left;\" target=\"_blank\"\u003e 📄 Data Sheet (PDF) \u003c\/a\u003e\u003c\/p\u003e","brand":"BRUSA HyPower","offers":[{"title":"Default Title","offer_id":45717160820819,"sku":"BRUSA-OBC768-3P","price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/6863\/2659\/files\/Brusa_Hypower_OBC768-3p.jpg?v=1781834213","url":"https:\/\/www.veeworks.au\/products\/brusa-hypower-obc7-obc768-3p","provider":"Veeworks","version":"1.0","type":"link"}